]> mj.ucw.cz Git - pciutils.git/blobdiff - lspci.man
pcilmr: Apply grading quirk for Ice Lake RC ports
[pciutils.git] / lspci.man
index 05e602eb0c4bf90f5525754f7fe3536c1aba2877..7907aeb8a5dcaa9dd6dd9cb8a51f0f806ed930fb 100644 (file)
--- a/lspci.man
+++ b/lspci.man
@@ -116,7 +116,7 @@ Show PCI vendor and device codes as both numbers and names.
 Use DNS to query the central PCI ID database if a device is not found in the local
 .B pci.ids
 file. If the DNS query succeeds, the result is cached in
 Use DNS to query the central PCI ID database if a device is not found in the local
 .B pci.ids
 file. If the DNS query succeeds, the result is cached in
-.B ~/.pciids-cache
+.B $XDG_CACHE_HOME/pci-ids
 and it is recognized in subsequent runs even if
 .B -q
 is not given any more. Please use this switch inside automated scripts only
 and it is recognized in subsequent runs even if
 .B -q
 is not given any more. Please use this switch inside automated scripts only
@@ -142,10 +142,10 @@ hexadecimal.  E.g., "0:" means all devices on bus 0, "0" means all functions of
 on any bus, "0.3" selects third function of device 0 on all buses and ".4" shows only
 the fourth function of each device.
 .TP
 on any bus, "0.3" selects third function of device 0 on all buses and ".4" shows only
 the fourth function of each device.
 .TP
-.B -d [<vendor>]:[<device>][:<class>]
-Show only devices with specified vendor, device and class ID. The ID's are
-given in hexadecimal and may be omitted or given as "*", both meaning
-"any value".
+.B -d [<vendor>]:[<device>][:<class>[:<prog-if>]]
+Show only devices with specified vendor, device, class ID, and programming interface.
+The ID's are given in hexadecimal and may be omitted or given as "*", both meaning
+"any value". The class ID can contain "x" characters which stand for "any digit".
 
 .SS Other options
 .TP
 
 .SS Other options
 .TP
@@ -167,7 +167,9 @@ Applies only to Linux systems with recent enough module tools.
 Invoke bus mapping mode which performs a thorough scan of all PCI devices, including
 those behind misconfigured bridges, etc. This option gives meaningful results only
 with a direct hardware access mode, which usually requires root privileges.
 Invoke bus mapping mode which performs a thorough scan of all PCI devices, including
 those behind misconfigured bridges, etc. This option gives meaningful results only
 with a direct hardware access mode, which usually requires root privileges.
-Please note that the bus mapper only scans PCI domain 0.
+By default, the bus mapper scans domain. You can use the
+.B -s
+option to select a different domain.
 .TP
 .B --version
 Shows
 .TP
 .B --version
 Shows
@@ -343,7 +345,7 @@ utility to download the most recent version.
 .B @IDSDIR@/pci.ids.gz
 If lspci is compiled with support for compression, this file is tried before pci.ids.
 .TP
 .B @IDSDIR@/pci.ids.gz
 If lspci is compiled with support for compression, this file is tried before pci.ids.
 .TP
-.B ~/.pciids-cache
+.B $XDG_CACHE_HOME/pci-ids
 All ID's found in the DNS query mode are cached in this file.
 
 .SH BUGS
 All ID's found in the DNS query mode are cached in this file.
 
 .SH BUGS