00 -> 7f INFO 0500006b Error/warning code 69 05 seen so far: 6905 (low pressure?), 8509 (no gas?), 6208 (ignition timeout?), 7606 (very low pressure), 0000 (OK) 00 -> 7f INFO 0500009b Warning code (different encoding) 05 09 seen so far: 0509 (low pressure?), 0000 (OK) 06 -> 7f: INFO 0500:006c Clock 00 78 year - 1900 02 month 1b day 04 day of week 17 hour 39 min 06 00 00 -> 7f INFO 0500:0213: 14 00/04/14, 02 (low pressure warning?), 0b (low pressure error), 09/0b (during no gas errors), 08/43/40 (during boot) 00 00 5b 00 -> 7f: INFO 0500:0219 00 93 outside temp * 64 00 0c pressure * 10 00 04 24 90 ff ff 00 00 03 -> 00: INFO 0500:0229 AGU.2 status 08 f4 floor heating temperature * 64 00 00 64 01 04 04/24/44/54/64 00 -> 03: INFO 0504:0227 AGU.2 control 0a f2 mixture modulation 00 03 03/04, looks like 03=pump on 07 -> 00 QUERY 053d0099 00 -> 07 ANSWER 053d0099 Periodically requested by 07 during errors 00 02 71 or: 00 02 36 (low pressure error) 06 -> 00 QUERY 053d009a 00 -> 06 ANSWER 053d009a Periodically requested by 06 and 07 during errors 00 85 09 00 68 00 00 00 00 00 00 00 or: 00 76 06 00 40 01 00 00 00 00 00 00 (low pressure error) 07 -> 00 QUERY 053d009c 00 -> 07 ANSWER 053d009c: Periodically requested by 07 during warnings 05 09 the same warning code as in 0500009b 00 00 00 00 00 00 00 00 00 -> 7f INFO 2d000211 Circuit 1 status 01 02 01=attenuated, 02=comfort 00 03 24 90 ff ff 00 02=pump on, 00=off 01 00 -> 7f INFO 2e000211 Circuit 2 status 00 -> 7f INFO 2f000211 Circuit 3 status 00 -> 7f: INFO 3100:0212 Hot water status 01 01 00/01 (looks like 01=pump on) 4d 45 if prev byte is 00, 4d if prev byte is 01 06 -> 00: INFO 3d2d:0215 Room 1 status 05 e9 temperature * 64 00 07 -> 00: INFO 3e2e:0215 Room 2 status 06 3d temperature * 64 00