]> mj.ucw.cz Git - pciutils.git/blob - lspci.man
Merge pull request #177 from OscarL/cache-loc-on-man-pages
[pciutils.git] / lspci.man
1 .TH lspci 8 "@TODAY@" "@VERSION@" "The PCI Utilities"
2 .SH NAME
3 lspci \- list all PCI devices
4 .SH SYNOPSIS
5 .B lspci
6 .RB [ options ]
7 .SH DESCRIPTION
8 .B lspci
9 is a utility for displaying information about PCI buses in the system and
10 devices connected to them.
11
12 By default, it shows a brief list of devices. Use the options described
13 below to request either a more verbose output or output intended for
14 parsing by other programs.
15
16 If you are going to report bugs in PCI device drivers or in
17 .I lspci
18 itself, please include output of "lspci -vvx" or even better "lspci -vvxxx"
19 (however, see below for possible caveats).
20
21 Some parts of the output, especially in the highly verbose modes, are probably
22 intelligible only to experienced PCI hackers. For exact definitions of
23 the fields, please consult either the PCI specifications or the
24 .B header.h
25 and
26 .B /usr/include/linux/pci.h
27 include files.
28
29 Access to some parts of the PCI configuration space is restricted to root
30 on many operating systems, so the features of
31 .I lspci
32 available to normal users are limited. However,
33 .I lspci
34 tries its best to display as much as available and mark all other
35 information with
36 .I <access denied>
37 text.
38
39 .SH OPTIONS
40
41 .SS Basic display modes
42 .TP
43 .B -m
44 Dump PCI device data in a backward-compatible machine readable form.
45 See below for details.
46 .TP
47 .B -mm
48 Dump PCI device data in a machine readable form for easy parsing by scripts.
49 See below for details.
50 .TP
51 .B -t
52 Show a tree-like diagram containing all buses, bridges, devices and connections
53 between them.
54
55 .SS Display options
56 .TP
57 .B -v
58 Be verbose and display detailed information about all devices.
59 .TP
60 .B -vv
61 Be very verbose and display more details. This level includes everything deemed
62 useful.
63 .TP
64 .B -vvv
65 Be even more verbose and display everything we are able to parse,
66 even if it doesn't look interesting at all (e.g., undefined memory regions).
67 .TP
68 .B -k
69 Show kernel drivers handling each device and also kernel modules capable of handling it.
70 Turned on by default when
71 .B -v
72 is given in the normal mode of output.
73 (Currently works only on Linux with kernel 2.6 or newer.)
74 .TP
75 .B -x
76 Show hexadecimal dump of the standard part of the configuration space (the first
77 64 bytes or 128 bytes for CardBus bridges).
78 .TP
79 .B -xxx
80 Show hexadecimal dump of the whole PCI configuration space. It is available only to root
81 as several PCI devices
82 .B crash
83 when you try to read some parts of the config space (this behavior probably
84 doesn't violate the PCI standard, but it's at least very stupid). However, such
85 devices are rare, so you needn't worry much.
86 .TP
87 .B -xxxx
88 Show hexadecimal dump of the extended (4096-byte) PCI configuration space available
89 on PCI-X 2.0 and PCI Express buses.
90 .TP
91 .B -b
92 Bus-centric view. Show all IRQ numbers and addresses as seen by the cards on the
93 PCI bus instead of as seen by the kernel.
94 .TP
95 .B -D
96 Always show PCI domain numbers. By default, lspci suppresses them on machines which
97 have only domain 0.
98 .TP
99 .B -P
100 Identify PCI devices by path through each bridge, instead of by bus number.
101 .TP
102 .B -PP
103 Identify PCI devices by path through each bridge, showing the bus number as
104 well as the device number.
105
106 .SS Options to control resolving ID's to names
107 .TP
108 .B -n
109 Show PCI vendor and device codes as numbers instead of looking them up in the
110 PCI ID list.
111 .TP
112 .B -nn
113 Show PCI vendor and device codes as both numbers and names.
114 .TP
115 .B -q
116 Use DNS to query the central PCI ID database if a device is not found in the local
117 .B pci.ids
118 file. If the DNS query succeeds, the result is cached in
119 .B $XDG_CACHE_HOME/pci-ids
120 and it is recognized in subsequent runs even if
121 .B -q
122 is not given any more. Please use this switch inside automated scripts only
123 with caution to avoid overloading the database servers.
124 .TP
125 .B -qq
126 Same as
127 .BR -q ,
128 but the local cache is reset.
129 .TP
130 .B -Q
131 Query the central database even for entries which are recognized locally.
132 Use this if you suspect that the displayed entry is wrong.
133
134 .SS Options for selection of devices
135 .TP
136 .B -s [[[[<domain>]:]<bus>]:][<device>][.[<func>]]
137 Show only devices in the specified domain (in case your machine has several host bridges,
138 they can either share a common bus number space or each of them can address a PCI domain
139 of its own; domains are numbered from 0 to ffff), bus (0 to ff), device (0 to 1f) and function (0 to 7).
140 Each component of the device address can be omitted or set to "*", both meaning "any value". All numbers are
141 hexadecimal.  E.g., "0:" means all devices on bus 0, "0" means all functions of device 0
142 on any bus, "0.3" selects third function of device 0 on all buses and ".4" shows only
143 the fourth function of each device.
144 .TP
145 .B -d [<vendor>]:[<device>][:<class>[:<prog-if>]]
146 Show only devices with specified vendor, device, class ID, and programming interface.
147 The ID's are given in hexadecimal and may be omitted or given as "*", both meaning
148 "any value". The class ID can contain "x" characters which stand for "any digit".
149
150 .SS Other options
151 .TP
152 .B -i <file>
153 Use
154 .B
155 <file>
156 as the PCI ID list instead of @IDSDIR@/pci.ids.
157 .TP
158 .B -p <file>
159 Use
160 .B
161 <file>
162 as the map of PCI ID's handled by kernel modules. By default, lspci uses
163 .RI /lib/modules/ kernel_version /modules.pcimap.
164 Applies only to Linux systems with recent enough module tools.
165 .TP
166 .B -M
167 Invoke bus mapping mode which performs a thorough scan of all PCI devices, including
168 those behind misconfigured bridges, etc. This option gives meaningful results only
169 with a direct hardware access mode, which usually requires root privileges.
170 By default, the bus mapper scans domain. You can use the
171 .B -s
172 option to select a different domain.
173 .TP
174 .B --version
175 Shows
176 .I lspci
177 version. This option should be used stand-alone.
178
179 .SS PCI access options
180 .PP
181 The PCI utilities use the PCI library to talk to PCI devices (see
182 \fBpcilib\fP(7) for details). You can use the following options to
183 influence its behavior:
184 .TP
185 .B -A <method>
186 The library supports a variety of methods to access the PCI hardware.
187 By default, it uses the first access method available, but you can use
188 this option to override this decision. See \fB-A help\fP for a list of
189 available methods and their descriptions.
190 .TP
191 .B -O <param>=<value>
192 The behavior of the library is controlled by several named parameters.
193 This option allows one to set the value of any of the parameters. Use \fB-O help\fP
194 for a list of known parameters and their default values.
195 .TP
196 .B -H1
197 Use direct hardware access via Intel configuration mechanism 1.
198 (This is a shorthand for \fB-A intel-conf1\fP.)
199 .TP
200 .B -H2
201 Use direct hardware access via Intel configuration mechanism 2.
202 (This is a shorthand for \fB-A intel-conf2\fP.)
203 .TP
204 .B -F <file>
205 Instead of accessing real hardware, read the list of devices and values of their
206 configuration registers from the given file produced by an earlier run of lspci -x.
207 This is very useful for analysis of user-supplied bug reports, because you can display
208 the hardware configuration in any way you want without disturbing the user with
209 requests for more dumps.
210 .TP
211 .B -G
212 Increase debug level of the library.
213
214 .SH MACHINE READABLE OUTPUT
215 If you intend to process the output of lspci automatically, please use one of the
216 machine-readable output formats
217 .RB ( -m ,
218 .BR -vm ,
219 .BR -vmm )
220 described in this section. All other formats are likely to change
221 between versions of lspci.
222
223 .P
224 All numbers are always printed in hexadecimal. If you want to process numeric ID's instead of
225 names, please add the
226 .B -n
227 switch.
228
229 .SS Simple format (-m)
230
231 In the simple format, each device is described on a single line, which is
232 formatted as parameters suitable for passing to a shell script, i.e., values
233 separated by whitespaces, quoted and escaped if necessary.
234 Some of the arguments are positional: slot, class, vendor name, device name,
235 subsystem vendor name and subsystem name (the last two are empty if
236 the device has no subsystem); the remaining arguments are option-like:
237
238 .TP
239 .BI -r rev
240 Revision number.
241
242 .TP
243 .BI -p progif
244 Programming interface.
245
246 .P
247 The relative order of positional arguments and options is undefined.
248 New options can be added in future versions, but they will always
249 have a single argument not separated from the option by any spaces,
250 so they can be easily ignored if not recognized.
251
252 .SS Verbose format (-vmm)
253
254 The verbose output is a sequence of records separated by blank lines.
255 Each record describes a single device by a sequence of lines, each line
256 containing a single
257 .RI ` tag :
258 .IR value '
259 pair. The
260 .I tag
261 and the
262 .I value
263 are separated by a single tab character.
264 Neither the records nor the lines within a record are in any particular order.
265 Tags are case-sensitive.
266
267 .P
268 The following tags are defined:
269
270 .TP
271 .B Slot
272 The name of the slot where the device resides
273 .RI ([ domain :] bus : device . function ).
274 This tag is always the first in a record.
275
276 .TP
277 .B Class
278 Name of the class.
279
280 .TP
281 .B Vendor
282 Name of the vendor.
283
284 .TP
285 .B Device
286 Name of the device.
287
288 .TP
289 .B SVendor
290 Name of the subsystem vendor (optional).
291
292 .TP
293 .B SDevice
294 Name of the subsystem (optional).
295
296 .TP
297 .B PhySlot
298 The physical slot where the device resides (optional, Linux only).
299
300 .TP
301 .B Rev
302 Revision number (optional).
303
304 .TP
305 .B ProgIf
306 Programming interface (optional).
307
308 .TP
309 .B Driver
310 Kernel driver currently handling the device (optional, Linux only).
311
312 .TP
313 .B Module
314 Kernel module reporting that it is capable of handling the device
315 (optional, Linux only). Multiple lines with this tag can occur.
316
317 .TP
318 .B NUMANode
319 NUMA node this device is connected to (optional, Linux only).
320
321 .TP
322 .B IOMMUGroup
323 IOMMU group that this device is part of (optional, Linux only).
324
325 .P
326 New tags can be added in future versions, so you should silently ignore any tags you don't recognize.
327
328 .SS Backward-compatible verbose format (-vm)
329
330 In this mode, lspci tries to be perfectly compatible with its old versions.
331 It's almost the same as the regular verbose format, but the
332 .B
333 Device
334 tag is used for both the slot and the device name, so it occurs twice
335 in a single record. Please avoid using this format in any new code.
336
337 .SH FILES
338 .TP
339 .B @IDSDIR@/pci.ids
340 A list of all known PCI ID's (vendors, devices, classes and subclasses). Maintained
341 at https://pci-ids.ucw.cz/, use the
342 .B update-pciids
343 utility to download the most recent version.
344 .TP
345 .B @IDSDIR@/pci.ids.gz
346 If lspci is compiled with support for compression, this file is tried before pci.ids.
347 .TP
348 .B $XDG_CACHE_HOME/pci-ids
349 All ID's found in the DNS query mode are cached in this file.
350
351 .SH BUGS
352
353 Sometimes, lspci is not able to decode the configuration registers completely.
354 This usually happens when not enough documentation was available to the authors.
355 In such cases, it at least prints the
356 .B <?>
357 mark to signal that there is potentially something more to say. If you know
358 the details, patches will be of course welcome.
359
360 Access to the extended configuration space is currently supported only by the
361 .B linux_sysfs
362 back-end.
363
364 .SH SEE ALSO
365 .BR setpci (8),
366 .BR pci.ids (5),
367 .BR update-pciids (8),
368 .BR pcilib (7)